Transite heat: is this really a big deal?

If you mention the word transite to about 90% of the population, they either think of HVAC ductwork installed below the concrete floor in a basement, or they assume you added an “e” onto the word transit. This ought to change.

The vast majority of sub-slab ductwork is not transite, and shouldn’t be labeled as such. Also, there’s no such thing as “transit” heat. Some spell-checker created this word by chopping off the letter e. It’s transite.

I’m no historian, but I’ve always been taught that transite was a cement-asbestos product. Wikipedia agrees, describing Transite as a brand created by Johns-Manville in 1929 for cement-asbestos products. At some point, the product transitioned from Transite to transite, just like Romex became romex and Sheetrock became sheetrock. At least in everyone’s minds.

The two components in a home most appropriately called transite are cement-asbestos gas vents and cement-asbestos sub-slab ducts.

Most sub-slab ducts are not transite

That’s right, most sub-slab ductwork here in Minnesota is not made from transite. It’s mostly PVC. When this ductwork is called transite, it’s implied that the ductwork contains asbestos. Don’t call it transite if the ductwork is not made from cement-asbestos. This creates confusion and unnecessary concern. Call it sub-slab ductwork. Transite ductwork was used in the 1960s and early 1970s.

Does it matter?

Yes, it contains asbestos… but that doesn’t mean it’s a problem. Thousands of products in homes may contain asbestos, and asbestos still hasn’t been banned in the United States. The hazard level with transite ductwork is extremely low.

Asbestos fibers are trapped in this material, and they’re not easily released into the air. My only concern with transite ductwork is the fact that it’s ductwork installed below the basement slab, and if water gets in there, it can be a big problem.

How to identify transite ductwork

It’s easy to identify transite ductwork by looking at it. The image below shows a rare view of the outside of a transite heat duct. In most homes, this portion of the duct is buried below the slab. It’s only visible in this case because it was in a split-level home.

transite heat duct exterior

Here’s a view of a transite duct from the inside. Click on the image for a larger, more detailed version. Note the spiral and rough fiber.

transite duct with water stains

Also, make note of the obvious water staining in the ductwork. This ductwork has surely been flooded in the past, which is the only concern I have with this material. That’s a topic all on its own, so please come back next week for my blog post on water in sub-slab ductwork.

If you remove a floor register and look at the cut edges of the ductwork, this will help to identify the material.

Floor register cover removed

If it’s transite, the cut edges will appear rough and fibrous.

Skinny Mirror inspecting transite

Here are a couple more photos showing transite ductwork:

Transite ductwork opening

Transite heat 2

No responses to “Transite heat: is this really a big deal?”

  1. Vickie Swenson
    June 26, 2018, 8:12 am

    This is great. I often refer to them as in-slab ducts, but will now start calling them sub-slab ducts. I agree that most are now PVC…some of the old sheet metal ducts have rusted out, allowing mice and rats to enter. I have one client in a slab on grade townhouse near wet lands with snakes entering her ducts; the home owners association tells the homeowners not to clean their ducts because they will get more cracks and more snakes! So she has to live with mold, because these ducts are major mold growers. One of my clients nearly died from her sub-slab ducts when stagnant water in the ducts caused bacteria to enter the HVAC which caused a lung infection that went sepsis. So frustrating!

  2. Reuben Saltzman
    June 27, 2018, 4:19 am

    Thank you, Vickie! Yes, the old metal ducts are definitely bad news. It’s hard to believe that anyone thought those were a good idea. The first time I saw that done, I couldn’t believe what I was seeing.

  3. Ron Wieber
    June 26, 2018, 10:25 am

    As usual, Reuben is right on from my POV + 30 years asbestos inspections! Good informative work!

  4. Reuben Saltzman
    June 27, 2018, 4:19 am

    Thank you, Ron!

  5. Brian
    June 26, 2018, 6:46 pm

    Do you have any thoughts on “Duct Armor”? There’s a ton of marketing information on the internet, but not much that’s on actual results.

    On one hand, it looks like the stuff used for trenchless drain replacements.

    On the other hand, it looks like a scam (who can possibly inspect the results).

  6. Reuben Saltzman
    June 27, 2018, 4:21 am

    Hi Brian,

    I’ll actually be mentioning Duct Armor in next week’s blog post about water in the ducts. I’ve never seen it installed, but we had a guy come out to our local ASHI meeting to talk about that stuff, and I was sold on it. It won’t keep water out of the ducts, but it’ll do just about everything else. I wouldn’t hesitate to try it.

  7. Water in sub-slab ductwork - Structure Tech Home Inspections
    July 3, 2018, 5:02 am

    […] last week’s blog post on transite heat, I explained that most sub-slab ductwork is not transite. It’s not transite heat, it’s […]

  8. Rick Carlberg
    July 20, 2018, 4:20 pm

    You mentioned the concerns with having this type of duct work cleaned but what about normal air movement through these ducts? Is this a concern as well with friable edges? Is it OK to have this material as long as you don’t try to clean it? Just wondering what you would recommend to your clients.
    Thanks

RSS feed for comments on this post. TrackBack URL

Leave a Reply